Are you facing problems with your Hengrui continuous centrifuge? Don't worry. We are here to help you. We’ll discuss some of the most frequent problems you’ll experience with these types of centrifuges and offer simple fixes for them.
Continuous Centrifuges: Typical Problems
One typical cause of problems with a continuous centrifuge is when the inlet or outlet becomes blocked. That can occur when dirt or debris gets lodged fresh inside and prevents the flow of the oil. To resolve this issue, pause the machine. Next, remove the inlet and outlet hoses. If you find any blockage, clear it with small brush. When you're finished cleaning, you can then reattach the hoses and start the machine.
A second problem occurs in the event that the centrifuge is vibrating or shaking during operation. This is possible if the load inside is unbalanced or if the machine is not properly aligned. To correct this, pause the machine and verify that the load is balanced. If necessary, shift the load so it’s balanced. And do be sure the centrifuge is in flat contact with the ground, to minimize vibration.
Operating, and Maintenance Problems of Continuous Centrifuges
If you have problems with the speed and movement of your continuous centrifuge, it could be the motor or drive belt that's at fault. In case of malfunction, stop the machine and inspect the motor and drive belt. Inspect for signs of fraying or cracking. There may be something wrong with the belt or the motor if you see either of these things. Also check tightness /alignment of all connections.
Problem Solving Solutions for Common Issues
Leaking from the seals / gaskets is a common complaint from people who use continuous centrifuge. This is possible as the seals deteriorate with time. To correct this, stop the machine and inspect the seals and gaskets for wear or damage. If they appear worn, take them out and replace them with fresh ones to counteract the drips.
Another issue is that motors can get too hot when they run, as with a centrifuge. This is caused by the cooling systems being blocked or not enough air flow. To work it round, verify that the cooling system is clean and not clogged. Ensure the machine is placed in a location with adequate air flow to prevent it from overheating.
Handful of Ways to Address Problems with Your Continuous Centrifuge
I f you have no idea how to resolve the issue with your continuous centrifuge, it is better to observe the user manual or get in touch with Hengrui customer service for guidance. Our staff can counsel you on how to search for and correct the most common problems, thus you're able to retain your machine's ideal condition.